首页 | 产品信息 | 技术研发 | 常规服务 | 订单下载 | 访客留言 | 联系我们  
 产品分类 
· 蛋白相关
·重组蛋白;
·蛋白提取试剂盒;
·蛋白定量试剂盒;
·蛋白纯化试剂;
·细胞培养添加蛋白因子;
·蛋白Marker
· 核酸相关
·吸附柱法核酸提取试剂盒;
·磁珠法核酸提取试剂盒
·免核酸提取样品保存液/核酸释放剂;
·核酸采集与保护套装;
·一次性病毒采样管套装;
·一步法新型冠状病毒荧光定量PCR试剂盒
·表达质粒
·一次性核酸胶体金试纸条
· 试剂盒相关
·ELISA 试剂盒;
·细胞凋亡检测试剂盒;
·细胞转染试剂;
·ECL高灵敏度化学发光试剂盒
· 抗体相关
·一抗;
·二抗;
·体外诊断(IVD)活性抗体;
·抗体纯化试剂
· CDMO服务
·细胞株开发;
·细胞培养工艺开发;
·蛋白纯化工艺开发;
·制剂工艺开发;
·中试放大生产;
·GMP生产服务
· 其他
·核酸清除剂
·灭菌注射用水
·荧光染料
 技术研发分类 
· 蛋白定制服务
· 抗体定制服务
· 试剂盒定制服务
· 课题项目服务
 常规服务分类 
· IF及IHC技术服务
· Western blot服务
· 蛋白纯化及标记服务
· 实时荧光定量PCR
产品信息 >> 试剂盒相关 >> ELISA 试剂盒;
Human u-Plasminogen Activator/Urokinase

Human u-Plasminogen Activator/Urokinase Quantikine ELISA Summary

Assay Type

Solid Phase   Sandwich ELISA

Format

96-well strip   plate

Assay Length

4.5 hours

Sample Type   & Volume Required Per Well

Cell   Culture Supernates (50 uL), Cell Lysates (50 uL), Serum (17 uL), EDTA Plasma   (17 uL), Heparin Plasma (17 uL), Urine (10 uL)

Sensitivity

4.17 pg/mL

Assay Range

31.3 - 2,000   pg/mL (Cell Culture Supernates, Cell Lysates, Serum, EDTA Plasma, Heparin   Plasma, Urine)

Specificity

Natural and   recombinant human uPA. This assay also recognizes uPA complexed with PAI-1 or   uPAR.

 

Cross-reactivity

< 0.5%   cross-reactivity observed with available related molecules.< 50% cross-species   reactivity observed with species tested

Interference

No significant   interference observed with available related molecules.

Product Summary

The Quantikine Human u-Plasminogen Activator/Urokinase Immunoassay is a 4.5 hour solid phase ELISA designed to measure uPA in cell culture supernates, cell lysates, serum, plasma, and urine. It contains NS0-expressed recombinant human uPA and antibodies raised against the recombinant factor. This immunoassay has been shown to accurately quantitate recombinant human uPA. Results obtained using natural human uPA showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for natural human uPA.

Preparation and Storage

Shipping

The product is   shipped at ambient temperature. Upon receipt, store it immediately at the   temperature recommended below.

Storage

Store the   unopened product at 2 - 8 °C. Do not use past expiration date.

Background: u-Plasminogen Activator (uPA)/Urokinase

u-Plasminogen Activator (uPA) is a serine protease that converts plasminogen to plasmin, with roles in a variety of normal and pathological processes that include cell migration and tissue destruction. uPA is a potent marker of invasion and metastasis in a variety of human cancers including breast, stomach, colon, bladder, ovarian, brain, and endometrium.

Long Name:

Urokinase-type   Plasminogen Activator

Entrez Gene   IDs:

5328 (Human);   18792 (Mouse)

Alternate   Names:

ATF; EC   3.4.21; EC 3.4.21.73; plasminogen activator, urokinase; PLAU; uPA; u-PA; uPlasminogen   Activator; u-Plasminogen Activator; urinary; Urokinase; urokinase-type   plasminogen activator

Assay Procedure

Refer to the product datasheet for the complete assay procedure.

Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.

1.     Prepare all reagents, standard dilutions, and samples as directed in the product insert.

2.     Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal.

3.     Add 50 μL of Assay Diluent to each well.

4.     Add 50 μL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 2 hours.

5.     Aspirate each well and wash, repeating the process 4 times for a total of 5 washes.

6.     Add 100 μL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours.

7.     Aspirate and wash 5 times.

8.     Add 100 μL Substrate Solution to each well.

9.     Add 100 μL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm.

上一篇:Human PD-L2/B7-DC    下一篇:Human IGFBP-rp1/IGFB
关于我们   |   诚聘英才   |   信息发布   |   新品推荐   |   技术支持

     电话:400-832-8698    地址:北京怀柔雁栖开发区光织谷东区二号楼 

   备案/许可证编号京ICP备2020036913号

京ICP备2020036913号    技术支持:华大网络