Human NCAM-1/CD56 DuoSet ELISA Summary Assay Type | Solid Phase Sandwich ELISA | Format | 96-well strip plate | Assay Length | 4.5 hours | Sample Type & Volume Required Per Well | 100 uL | Sensitivity | 0.036 ng/mL | Assay Range | 78.1 - 5,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Human Milk) | Specificity | Natural and recombinant human NCAM-1/CD56 | Cross-reactivity | < 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested | Interference | No significant interference observed with available related molecules. |
Product Summary This DuoSet ELISA Development kit contains the basic components required for the development of sandwich ELISAs to measure natural and recombinant human NCAM-1/CD56. The suggested diluent is suitable for the analysis of most cell culture supernate samples. Diluents for complex matrices, such as serum and plasma, should be evaluated prior to use in this DuoSet. Preparation and Storage Shipping | The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below. | Storage | Store the unopened product at 2 - 8 °C. Do not use past expiration date. |
Background: NCAM-1/CD56Neural cell adhesion molecule 1(NCAM-1) is a multifunctional member of the Ig superfamily. It belongs to a family of membrane-bound glycoproteins that are involved in calcium-independent cell matrix and homophilic or heterophilic cell-cell interactions. NCAM-1 specifically binds to heparan sulfate proteoglycans, the extracellular matrix protein agrin, and several chondroitin sulfate proteoglycans that include neurocan and phosphocan. Long Name: | Neural Cell Adhesion Molecule | Entrez Gene IDs: | 4684 (Human); 17967 (Mouse); 24586 (Rat) | Alternate Names: | CD56 / NCAM-1; CD56 antigen; CD56; MSK39; NCAM1; N-CAM-1; NCAM-1; NCAMantigen recognized by monoclonal 5.1H11; neural cell adhesion molecule 1; neural cell adhesion molecule, NCAM |
Assay Procedure Refer to the product datasheet for the complete assay procedure. Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. 1. Prepare all reagents, standard dilutions, and samples as directed in the product insert. 2. Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal. 3. Add 50 μL of Assay Diluent to each well. 4. Add 50 μL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 2 hours. 5. Aspirate each well and wash, repeating the process 4 times for a total of 5 washes. 6. Add 100 μL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours. 7. Aspirate and wash 5 times. 8. Add 100 μL Substrate Solution to each well. 9. Add 100 μL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm. |