Human Osteocalcin Quantikine ELISA Kit Summary Assay Type | Solid Phase Sandwich ELISA | Format | 96-well strip plate | Assay Length | 4.5 hours | Sample Type & Volume Required Per Well | Cell Culture Supernates (50 uL), EDTA Plasma (50 uL) | Sensitivity | 0.898 ng/mL | Assay Range | 2.0 - 64 ng/mL (Cell Culture Supernates, EDTA Plasma) | Specificity | Natural and recombinant human Osteocalcin | Cross-reactivity | < 0.5% cross-reactivity observed with available related molecules.Cross-species reactivity observed with 1 or more species tested | Interference | No significant interference observed with available related molecules. |
Product Summary The Quantikine Human Osteocalcin Immunoassay is a 4.5 hour solid-phase ELISA designed to measure human Osteocalcin in cell culture supernates and EDTA plasma. It contains synthetic human Osteocalcin and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human Osteocalcin showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for naturally occurring human Osteocalcin. Preparation and Storage Shipping | The product is shipped at ambient temperature. Upon receipt, store it immediately at the temperature recommended below. | Storage | Store the unopened product at 2 - 8 °C. Do not use past expiration date. |
Background: OsteocalcinOsteocalcin, also named Bone gamma-carboxyglutamic Acid Protein, is a secreted protein whose expression is restricted to cells of the osteoblast lineage. It has been frequently used as a marker for osteoblast lineage cells. Long Name: | Bone gamma-Carboxyglutamate [gla] Protein | Entrez Gene IDs: | 632 (Human); 12096 (Mouse); 25295 (Rat) | Alternate Names: | BGLAP; BGP; bone gamma-carboxyglutamate (gla) protein (osteocalcin); bone gamma-carboxyglutamate (gla) protein; Bone Gla protein; Gamma-carboxyglutamic acid-containing protein; OC; OCN; Osteocalcin |
Assay Procedure Refer to the product datasheet for the complete assay procedure. Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. 1、Prepare all reagents, standard dilutions, and samples as directed in the product insert. 2、Remove excess microplate strips from the plate frame, return them to the foil pouch containing the desiccant pack, and reseal. 3、Add 50 μL of Assay Diluent to each well. 4、Add 50 μL of Standard, control, or sample to each well. Cover with a plate sealer, and incubate at room temperature for 2 hours. 5、Aspirate each well and wash, repeating the process 4 times for a total of 5 washes. 6、Add 100 μL of Conjugate to each well. Cover with a new plate sealer, and incubate at room temperature for 2 hours. 7、Aspirate and wash 5 times. 8、Add 100 μL Substrate Solution to each well. 9、Add 100 μL of Stop Solution to each well. Read at 450 nm within 30 minutes. Set wavelength correction to 540 nm or 570 nm. |